for more info goto www.canbus-info.com


09/02/2010 04:45 AM
Re: [CANLIST] CAN bootloader of XC16x

... Hello Senmeis, you will need a special Programm on your PC. The application note "CAN Bootstrap Loader for XC16x" is using two evaluation boards, one fort


09/01/2010 05:10 AM
[CANLIST] CAN bootloader of XC16x

Hello, I am using XC164CM of Infineon. The question is, how can I use CAN bootloader to program the internal flash. On websites I found these two application


08/21/2010 05:11 AM
[CANLIST] can4linux wit new FlexCAN support

Hello, The can4linux project hostet on https://sourceforge.net/projects/can4linux/ was recently updated to support the FlexCAN modules which can be found in


08/12/2010 11:53 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

After looking carefully at the traffic MCP2515 reports on the SPI side i found the problem Al Pothoof states. A while after system wakes up on bus traffic


08/05/2010 06:49 PM
Re: [CANLIST] Fault tolerant Canbus TJA1054

... itself). Basically, I kept tweaking the ISR, making it a little cleaner and a little faster all the time. Eventually, the problem eased up and then


08/05/2010 06:06 PM
Re: [CANLIST] Fault tolerant Canbus TJA1054

I wish I had been paying more attention to my e-mails because I think I've seen the underlying issue before. Then again, it presented itself a little


08/04/2010 03:27 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

Finally after a lot time trying every possilble thing that would cause the problem i found that was an SPI issue. I was running at SPI mode 0,0 @ 2,5Mhz which


07/29/2010 03:29 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

I will try this with the resistors to 5V and Gnd and let you know by tomorrow. But from what i have seen by today i don't think it is a termination issue in my


07/28/2010 09:39 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

Hello George, If you have 2 nodes and the minimum value of the termination on the RTH and RTL is 500 Ohms (as the datasheet states), I think you have a problem


07/28/2010 02:56 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

Hello Kees, I am afraid that i did not made clear in my message that i try to communicate with this radio when it is out of the car. So the only nodes are this


07/27/2010 09:24 AM
Re: [CANLIST] Fault tolerant Canbus TJA1054

Hello George, In my opinion the fault tolerant CANbus in the car will be tuned for a 100 Ohms termination result. With the 1500 Ohms of the radio it means


07/27/2010 02:53 AM
[CANLIST] Fault tolerant Canbus TJA1054

Hello, I am trying to comunicate with a car radio via canbus. The radio uses fault tolerant canbus @ 50kbps with TJA1054 transceiver. My system uses a


07/26/2010 01:04 PM
Re: [CANLIST] Selecting capacitor value for split terminations

Hello Shane, Please do not try to use the Vref pin of the 3.3-V for split termination stabilization -- or any device other then the TJA1040 or HVD1040 or


07/26/2010 12:46 PM
Re: [CANLIST] EFT (burst") immunity EN61000-4-4

Hello Oliver, For 61000-4-4, I believe no bit error was the specification -- the customer's requirement. And yes, this is the only transceiver in the world to


07/26/2010 11:59 AM
Re: [CANLIST] EFT (burst") immunity EN61000-4-4

Hello Steve, (SN65HVD252) ... 61000-4-4 doesn't state a requirement but a test method. EN61000-6-2 or the product standards define requirements,